silverFoam

FAQ: How to prepare a loft for PUR foam spraying — a checklist...

silverFoam Ag40 open-cell foam

Light insulation for lofts and wooden structures

Elastic spray foam with low weight and low diffusion resistance, intended for dry, light partitions.

Find the Artist Compare Foams

Open-cell foam

silverFoam Ag40 for lightweight, dry building elements

silverFoam Ag40 is a light PUR foam spray applied. After combining the ingredients, it increases in volume and adapts to the space between the elements of the structure.

Its low weight and low diffusion resistance direct it primarily to attics, wooden ceilings and frame walls. The vapor barrier, ventilation and protective layers always require separate confirmation.

PRODUCT DATA

Key values of silverFoam Ag40

01

Density 7–10 kg/m³

Small additional load of light construction.

02

λD 0,038 W/(m·K)

Declared thermal conductivity by product material.

03

μ ≤ 5

Low coefficient of diffusion resistance of water vapour.

04

Class E

Declared reaction to product fire.

Drum of the silverFoam Ag40 open-cell PUR foam system

silverFoam Ag40 SYSTEM

The product is one element of finished insulation

The material parameters are important only in combination with the appropriate thickness, correct arrangement of layers and controlled application. Therefore, the product card does not replace the identification of a specific building.

The addition of active silver is part of the silverFoam Ag40 recipe. However, it does not replace a dry substrate, a tight roof, proper ventilation or protection of the building element against moisture.

Ready insulation of the attic with open cell foam silverFoam Ag40

TYPE OF APPLICATIONS

Where the small mass and the exact details count

Spraying makes it easier to create a continuous layer at rafters, collar beams, installations and other places with complex geometry. silverFoam Ag40 is used in dry building elements, protected from direct water exposure.

  • utility and non-use lofts
  • scowls and mowing spaces
  • Timber floors and ceilings
  • skeletal walls and light partitions

silverFoam Ag40 SPECIFICATIONS

Declared Product Properties

The values come from the product materials. The current declaration of performance of the relevant batch should be used for calculations and design.

PropertyDeclared valueReference document
Appearance density7–10 kg/m³silverFoam Ag40 product material
Thermal conductivity including ageingλD = 0,038 W/(m·K)PN-EN 14315-1:2013
Water vapour diffusion resistance factorμ ≤ 5PN-EN 14315-1:2013
Short-term saturation at partial immersion≤ 11 kg/m²PN-EN 14315-1:2013
Reaction to fireClass EPN-EN 14315-1:2013
Before using the values in your project, check the current technical data sheet and declaration of performance.

STANDARD OF APPLICATION

From substrate preparation to layer reception

The quality of insulation depends on the performance conditions as much as on the product itself.

01

Assessment of the bulkhead

Verification of structure, roof tightness, humidity and ventilation.

02

Preparation

Dry and stable substrate and securing the installation and equipment.

03

Controlled spray

Application conditions, component proportions and construction of agreed thickness.

04

Over.

Check the continuity, details and documentation before covering the isolation.

QUESTIONS ABOUT silverFoam Ag40

FAQ: open cell foam silverFoam Ag40

FAQ

01

Is silverFoam Ag40 suitable only for the attic?

No. Typical applications are also wooden ceilings and frame walls. However, each building element requires an assessment of humidity, layer arrangement and method of covering the foam.

02

Is silverFoam Ag40 replacing vapour control layer?

This assumption should not be made. The need and method of creating a vapor barrier layer result from the design of the building element, the conditions of use and the thermal and humidity analysis.

03

What depends on the thickness of the foam in the attic?

From the required insulation, declared lambda, geometry and layer arrangement. Thickness should be derived from calculations or design, not a single value used for each building.

04

Can you spray foam on damp wood?

The substrate must meet the requirements of the product and application technology. Damp, dirty or unstable wood requires first removing the cause of the problem and proper preparation.

05

When do you check your insulation?

Before covering with boards or applying subsequent layers. Continuity, detail and the agreed method of thickness control can then be assessed.

ATTIC OR LIGHTWEIGHT BUILDING ELEMENT

Check if the silverFoam Ag40 matches your building

Upload photos, dimensions, location and information about existing layers. The contractor will assess the building element and prepare the scope of work.