Gdańsk, pomorskie. Scope: insulating the roof slopes, knee walls and gable walls, including the details around the windows. Area approximately 156 m²; insulation: open-cell foam.
A loft conversion in a building after a complete renovation. A complex arrangement of roof slopes, a new steel structure reinforcing the floor and more than a dozen windows: roof windows on both slopes and smaller windows set into the masonry knee walls. Plenty of light and views, but also many potential thermal bridges from an insulation perspective.
Heat escapes evenly and predictably across a simple roof slope. Each window introduces a frame and a narrower space to fill. The more of these points there are, the less the material alone matters and the more carefully the insulation details must be executed.




Illustrative photos.
Scope of work
Parameters
- Working area: approximately 156 m².
- Type of insulation: open-cell silverFoam Ag40 foam.
- Specified layer thickness: 25 cm.
- Main scope: insulating the roof slopes, knee walls and gable walls, including the window reveals.
Challenge: six windows mean six times as much detail
A roof window interrupts the roof slope and the line of rafters. The structure transfers the loads to cross-members above and below the opening. Around the frame, there is a narrow space at the reveals that becomes narrower at the corners.
Wool cannot be squeezed in there without being crushed, and crushed wool ceases to insulate. The effect is usually visible after the first winter: condensation on the frame, sometimes mold in the corner.
PUR foam reaches these spaces differently. It expands into the available space and fills gaps without cutting or fitting. This is precisely the kind of roof geometry where spray application offers an even greater advantage.
The walls as well as the roof slopes
The roof alone accounts for less than half the challenge in this attic. The knee and gable walls are masonry, partly built from bricks retained from the original structure, with irregular thicknesses and visible lintels above the window openings. Without insulation, they would become the main route for heat loss even if the roof slopes were perfectly insulated.
Spray insulation was therefore also applied to the walls, between the previously installed lining profiles. Applied directly to the masonry, the foam follows its uneven surface without leaving air voids behind the insulation, as boards do on uneven surfaces. The lintels and window reveals in the knee walls required particular attention, as the masonry is thinnest at these points.
The most important detail, however, was completing the junction between the roof slopes and walls. At the wall plate, both insulation layers must meet without a gap. A break here creates a cold strip along the entire room, precisely where the slope meets the wall.
Work process
We began by inspecting the roof slopes: we checked the moisture content and stability of the substrate, the membrane, the installation of the windows and the flashings. We also checked the condition of the knee- and gable-wall masonry and the moisture content of the structural timber.
We protected the window frames, services, lining profiles and steel structural elements. With so many windows, masking is a separate stage that takes longer than most schedules allow.
We applied the foam in layers, checking that it expanded evenly. We treated the window reveals separately to connect the layer beside the frame to the roof or wall insulation. We also checked the junctions at the wall plate, rafters, floor structure and service penetrations, and around the steel beams and columns.
After application, we visually inspected the surface and filled in the critical areas.
Outcome for the client
The attic received a continuous insulation layer covering the roof slopes, knee and gable walls, and all window reveals. The boundary of the warm zone is unbroken, including at the roof-to-wall junction. The areas most vulnerable to local cooling were fully sealed before the lining was installed.
We gave the client recommendations for the next stages of work, particularly ventilation, lining installation and documenting the layers before they are covered.
Key points to remember
- The quality of attic insulation around roof windows depends on the reveals, rather than the middle of the roof slope.
- Every window introduces trimmer beams and narrow spaces where boards and rolls of insulation are least effective.
- Knee and gable walls must be insulated together with the roof slopes. Their junction at the wall plate is usually the weakest point.
- On uneven old masonry, foam adheres without the air voids that boards leave behind on every uneven surface.