silverFoam

FAQ: How to compare offers of PUR foam installers?

Waterside buildings

Isolation tailored to moisture and aggressive environment

In the marina, we first assess ventilation, the condition of the metal and the path of moisture, and only then we select a spray system.

Find the Artist Compare Foams

OVERVIEW AND CONDITIONS

Is PUR foam the right solution here?

The proximity of water increases air humidity and the risk of condensation and corrosion. Foam can insulate dry building envelopes, but it does not replace coatings intended for permanent contact with water.

Good project begins with an assessment of the structure and conditions, not just the square footage. The product, thickness and method of protection of the layer should be described before work begins.

KEY DECISIONS

What do you need to confirm?

01

Separation state

Substrate, existing layers, humidity and places to be repaired.

02

System selection

Type of foam and thickness resulting from the design and expected effect.

03

Layer protection

The method of protecting foam and reception from the next stage of construction.

BENEFITS OF WELL-DESIGNED SPRAY INSULATION

What can be achieved in the correct execution?

The effect depends on the complete building element system, material parameters, surface preparation and application quality.

01

Continuity of insulation in dry technical zones

Continuity must also be checked on connections to adjacent bulkheads.

02

Ability to accurately perform metal construction details

Corners, transitions, installations and restricted access areas require the most attention.

03

Selection of the system with regard to the moist environment

The correct effect depends on the product, the thickness and the conditions of the application.

04

Clear separation of thermal insulation from water protection

Confirm the scope of work and the final inspection procedure in the quotation before spraying begins.

PUR foam marina objects – an example partition

PLACE OF APPLICATION

Where is this solution being considered?

The scope should be described by a specific plane and its layers. The same name of a room may mean a completely different structure and working conditions.

  • service and storage buildings of marinas
  • dry technical zones
  • roofs and walls of sheet metal
  • ground partitions exposed to humid air
Marine objects – selection of spray insulation system

PRODUCT SELECTION

What kind of foam to choose?

In demanding but dry technical areas, closed-cell foam may be considered. The substrate must be dry, stable and protected against corrosion, and the finished layer must be properly protected.

Border condition: PUR foam is not a coating for constant immersion and does not replace water protection.

STANDARD OF IMPLEMENTATION

From recognition to isolation reception

Each stage reduces a different risk. The layer should not be covered until the agreed details have been checked.

01

Recognition

Construction, humidity, access, installations, existing layers and expected effect.

02

Preparation

Stable, clean and properly dry substrate and environmental protection.

03

Application

Controlled spray parameters, layer work and current continuity control.

04

Over.

Check details, agreed thickness and documentation before further work.

Marine facilities – control of details before reception

IMPLEMENTING RISK

What's not to miss?

The most common problems result from rushing the preparation or covering the insulation without inspecting it. Discuss these points with the installer.

  • mixing of insulation with coating for continuous immersion
  • spray on corroded or moist metal
  • lack of control of ventilation and dew point
  • leaving foam unprotected in the UV zone

EVALUATION PREPARATION

What should I give the contractor before the first conversation?

A few specific pieces of information are enough to distinguish a simple project from an object that requires an inspection or additional documentation.

01

Location and time limit

Locality, stage of construction and planned date of construction and insulation cover.

02

Photos of the whole surface

View of partitions, substrates, difficult details, installations and places with limited access.

03

Actual metres

Surface area of the planes intended for spraying, not just the usable surface.

04

Design and Layers

Separation section, type of structure, existing insulation and expected effect.

QUESTIONS BEFORE EXCLUSION

The most common questions: marina objects

FAQ

01

Is PUR foam suitable for this use?

In demanding but dry technical areas, closed-cell foam may be considered. The substrate must be dry, stable and protected against corrosion, and the finished layer must be properly protected. The final decision should be confirmed based on the design, substrate condition and documentation of the specific system.

02

What do you need to check before you spray?

The most important are: moisture source, dew point, ventilation, corrosion and the possibility of periodic flooding. The contractor should also confirm the temperature, access and scope of protection of elements that will not be covered with foam.

03

What does PUR foam replace in this bulkhead?

PUR foam is not a coating for constant immersion and does not replace water protection.

04

What to send to the preliminary valuation?

Provide the city, approximate spray application area, building type and planned date. Include photos of the entire building element, details, installations and existing layers.

05

What is the final price?

From the surface and thickness of the layer, type of system, geometry, condition of the substrate, access, number of protections, required foam protection and organisation of work on the facility.

QUOTE FOR A SPECIFIC BUILDING ELEMENT

Show contractors real investment conditions.

Send photos, location and square footage. The silverFoam contractor will verify the selection of the system, preparation of the substrate and the scope needed for the offer.